Sunday, 20 December 2015
Tuesday, 15 September 2015
MULTIPLEXER with REAL TIME EXAMPLE
Definition: In electronics, a multiplexer (or mux) is a device that selects one
of several analog or
digital input signals and forwards the
selected input into a single line. A multiplexer of 2n inputs has n select lines, which are used to select which
input line to send to the output.
REAL TIME EXAMPLE FOR
MULTIPLEXER
:
Sometimes we need to Display four values in one LCD O/p
Screen so what should we do ? The answer is so simple we use a keypad or any
input to select what we need to display .
That signal is input for micro controller and it
produces two output signals which we use as select lines to the Multiplexer so
that we can select one o/p signal out of four inputs.
The Multiplexer output is fed to the Micro controller, Inside
micro controller converts Analog to Digital and it sends to output port to the
LCD Display.
The LCD Display’s the required values, all this process is
done by msec.
Note : we will use a Driver circuit in between sensor and multiplexer and multiplexer output can be a digital or analog depends on inputs.
Friday, 21 August 2015
Roles and Responsibility's of Component Engineer.
Component Engineer Roles and Responsibility's :
- Component Engineer mainly works to maintain the Production of Product's continuously without any Failure's.
- Component Engineer identifies alternatives for obsolete components.
- Reduce the cost of production by suggesting The component which have less cost and same characteristics.
- Increase the efficiency of the Product by analyzing the Test Reports of Products.
1.BOM(Bill of material) SCRUBBING :
BOM Scrubbing means we have to identify all the components which are present in BOM are ACTIVE and ROHS (Reduction of Hazardous Substance) compliance are not. If all the component are ACTIVE and ROHS compliance then we no need to do anything. If any component is not ACTIVE or ROHS Compliance then we have to identify the alternate component for that part which have ROHS compliance and cost also need to take criteria.
BOM Scrubbing means we have to identify all the components which are present in BOM are ACTIVE and ROHS (Reduction of Hazardous Substance) compliance are not. If all the component are ACTIVE and ROHS compliance then we no need to do anything. If any component is not ACTIVE or ROHS Compliance then we have to identify the alternate component for that part which have ROHS compliance and cost also need to take criteria.
we have to update all the BOM Components to ACTIVE and ROHS compliance. If we can't find any Component to identify the environment where the component is used if it is compulsory ROHS then suggest to change the design for design engineer.
2.Identify the alternate for OBSOLESCENCE components :
- Whenever the Existing Component is Obsolete we have to identify the alternate Component to the Obsolete component to maintain continuous Production without any break.
- go to the manufacture's website and see for the part status is active or not and check the quantity in distributor's list (DIGI KEY, MOUSER ....) also.
- suppose in manufacture website don't find out the part status is active or not then check for stock other wise ask the manufacture for that part status through mail or phone.
Reasons for component Obsolete ?
There are many reason behind the component Obsolete some of the scenario's i will discuss here :
When the Component manufactures stop the Production due to less demand for that component so we will get affected by this action
OR
There is a technology development the component manufactures improve the component with new developments which will change the component physical dimension or characteristics so that they stop the existing Product and start the New Product Development then we will get Affect by this.
OR
The existing Component is not a ROHS compliance due to this the government Ban or component manufactures decide to go stop that Part production.
Subscribe to:
Posts (Atom)